Synchrotron SAXS data from solutions of monomeric bovine serum albumin in 20 mM Tris, 142 mM NaCl, 5 % Glycerol, 1mM DTT, pH 7 were collected on the BM29 SAXS beam line at the ESRF (Grenoble, France) using a 2D Photon counting Pilatus 1M-W pixel detector (I(s) vs s; s = 4π sin θ/λ, where 2θ is the scattering angle and λ=0.099 nm). Forty successive 1 s frames were collected through a BSA elution peak from a size-exclusion chromatography column (GE Healthcare Superdex 200 10/300 GL at 0.5 ml/min; initial load concentration = 10 mg/ml). The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank (derived from the SEC running solvent) was subtracted and the individual solvent-corrected SAXS profiles were scaled and averaged.
Concentration min = UNKNOWN
|
|