MWI(0) | 11 | kDa |
MWexpected | 20 | kDa |
VPorod | 22200 | nm3 |
log I(s)
4.05×10-3
4.05×10-4
4.05×10-5
4.05×10-6
|
s, nm-1
|
|
|
|
|
|
|
X-ray synchrotron radiation scattering data from solutions of the C-terminal catalytic domain of Suppressor of Copper Sensitivity C protein (ScsC) protein from Proteus mirabilis in 10 mM HEPES 150mM NaCl, pH 7.4 were collected on the SAXS/WAXS beam line of the Australian Synchrotron (Melbourne, Australia) using a 2D Photon counting Pilatus 1M-W pixel detector (s = 4π sin θ/λ, where 2θ is the scattering angle). Thirty eight successive 1 second frames were collected across solute concentrations of 0.1-10.0 mg/ml at a sample temperature of 10°C. The SAXS data displayed this entry was derived from a 0.50 mg/ml sample. The data were normalized to the intensity of the transmitted beam and radially averaged and the scattering of the solvent-blank was subtracted.
|
|