MWexperimental | 134 | kDa |
MWexpected | 125 | kDa |
log I(s)
6.10×101
6.10×100
6.10×10-1
6.10×10-2
|
s, nm-1
|
|
|
|
|
Synchrotron SAXS
data from solutions of
Hydrolytically Degradable Polymer Micelles for Drug Delivery (structure of hydrophobic substituent - cholest-4-en-3-one) with Dox (10%)
in
phosphate buffer saline (PBS) (pH 5.0), pH 5
were collected
on the
EMBL X33 beam line
at the DORIS III, DESY storage ring
(Hamburg, Germany)
using a Pilatus 1M-W detector
at a sample-detector distance of 2.7 m and
at a wavelength of λ = 0.154 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
One solute concentration of 10.00 mg/ml was measured
at 20°C.
Eight successive
15 second frames were collected.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Tags:
X33
|
|