Synchrotron SAXS
data from solutions of
Mus musculus Iho1 coiled-coiled with N-terminal SUMO-tag
in
25 mM HEPES-NaOH, 500 mM NaCl, 5 mM EDTA, 5% glycerol, 1 mM DTT, pH 7.5
were collected
on the
SWING beam line
at the SOLEIL storage ring
(Saint-Aubin, France)
using a Eiger 4M detector
at a sample-detector distance of 2 m and
at a wavelength of λ = 0.099 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
In-line size-exclusion chromatography (SEC) SAS was employed. The SEC parameters were as follows: A 90.00 μl sample
at 19.4 mg/ml was injected at a 0.20 ml/min flow rate
onto a Shodex KW404-4F column
at 15°C.
960 successive
0.990 second frames were collected.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
|
|