MWexperimental | 43 | kDa |
MWexpected | 46 | kDa |
VPorod | 59 | nm3 |
log I(s)
1.69×100
1.69×10-1
1.69×10-2
1.69×10-3
|
s, nm-1
|
|
|
|
|
|
|
Synchrotron SAXS data from solutions of M. polymorpha auxin response factor 3 in 20 mM Tris-HCl, 150 mM NaCl, 1 mM DTT, pH 8 were collected on the BL11 - NCD beam line at ALBA (Cerdanyola del Vallès, Barcelona, Spain) using a ADSC Quantum 210r detector at a sample-detector distance of 2.6 m and at a wavelength of λ = 0.1 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). One solute concentration of 3.50 mg/ml was measured at 20°C. 20 successive 0.500 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
CAUTION: Dmax appears underestimated. |
|