Conformational analysis of a genetically encoded FRET biosensor by SAXS.
Mertens HD,
Piljić A,
Schultz C,
Svergun DI
Biophys J
102(12):2866-75
(2012 Jun 20)
|
|
|
Sample: |
CYNEX4 FRET probe, (eYFP-AnnexinA4-eCFP) monomer, 93 kDa Homo sapiens protein
|
Buffer: |
50 mM HEPES 150 mM NaCl 1 mM EGTA, pH: 7.5 |
Experiment: |
SAXS
data collected at EMBL X33, DORIS III, DESY on 2010 Sep 11
|
|
RgGuinier |
3.7 |
nm |
Dmax |
12.8 |
nm |
VolumePorod |
135 |
nm3 |
|
|
|
|
|
Sample: |
CYNEX4 FRET probe, (eYFP-AnnexinA4-eCFP) T266D mutant monomer, 93 kDa Homo sapiens protein
|
Buffer: |
50 mM HEPES 50 mM KCl, pH: 7.5 |
Experiment: |
SAXS
data collected at EMBL X33, DORIS III, DESY on 2010 Sep 11
|
|
RgGuinier |
4.1 |
nm |
Dmax |
14.4 |
nm |
VolumePorod |
146 |
nm3 |
|
|
|
|
|
Sample: |
Annexin-A4 monomer, 36 kDa Homo sapiens protein
|
Buffer: |
50 mM HEPES 50 mM KCl, pH: 7.5 |
Experiment: |
SAXS
data collected at EMBL X33, DORIS III, DESY on 2010 Sep 11
|
|
RgGuinier |
2.4 |
nm |
Dmax |
7.6 |
nm |
VolumePorod |
54 |