MWexperimental | 1419 | kDa |
MWexpected | 1264 | kDa |
log I(s)
5.48×103
5.48×102
5.48×101
5.48×100
|
s, nm-1
|
|
|
|
|
Synchrotron SAXS
data from solutions of
Hexamer - monomer equilibrium of Glutamate Synthase
in
25 mM Hepes/KOH, 1 mM EDTA, 1 mM dithiothreitol, pH 7.5
were collected
on the
EMBL X33 beam line
at the DORIS III, DESY storage ring
(Hamburg, Germany)
using a MAR 345 Image Plate detector
at a sample-detector distance of 2.7 m and
at a wavelength of λ = 0.15 nm
(I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle).
One solute concentration of 0.80 mg/ml was measured.
Two successive
60 second frames were collected.
The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Cell temperature = UNKNOWN. Storage temperature = UNKNOWN
Tags:
X33
|
|