MWexperimental | 139 | kDa |
MWexpected | 155 | kDa |
VPorod | 240 | nm3 |
log I(s)
4.50×10-2
4.50×10-3
4.50×10-4
4.50×10-5
|
s, nm-1
|
|
|
|
|
|
|
|
|
Synchrotron SAXS data from solutions of the Nesprin-4-KASH/SUN1 6:6 complex in 20 mM Tris pH 8.0, 150 mM KCl, were collected on the B21 beam line at the Diamond Light Source (Didcot, UK) using a Pilatus 2M detector at a wavelength of λ = 0.095 nm (I(s) vs s, where s = 4πsinθ/λ, and 2θ is the scattering angle). In-line size-exclusion chromatography (SEC) SAS was employed. The SEC parameters were as follows: A 100.00 μl sample at 17 mg/ml was injected at a 0.50 ml/min flow rate onto a GE Superdex 200 Increase 10/300 column at 20°C. 31 successive 3 second frames were collected. The data were normalized to the intensity of the transmitted beam and radially averaged; the scattering of the solvent-blank was subtracted.
Storage temperature = UNKNOWN. Sample detector distance = UNKNOWN |
|